All insights
Technology

Using AI to read airworthiness directives: what a good review looks like

AI can draft a directive assessment in minutes. Here is how a CAMO should check that draft, and what the record needs to show.

A
Anandbabu
14 Sep 20268 min read
Key points
  • Treat the AI output as a draft assessment, never as the assessment itself.
  • Check applicability against the actual configuration of each aircraft, not just the type.
  • Record who reviewed the draft, what they changed and why.

Directive volume keeps rising, and each one needs a careful applicability review. AI tools can now read a new airworthiness directive and produce a draft assessment in minutes. That saves real time, but only if the CAMO treats the result as a draft and reviews it properly.

This guide sets out what a good AI assisted review looks like.

What the AI should produce

A useful draft lists the directive number and effective date, the applicability statement, the affected models, part numbers and serial ranges, the required actions, the compliance times and any terminating action. Each item should link back to the paragraph it came from. If the tool cannot point to the source, the item should not be trusted.

Step one: read the applicability yourself

Before looking at the draft, read the applicability paragraph in full. Note any conditions that depend on modification status, installed components or previous compliance with another directive. These conditions are where automated reading is most likely to go wrong.

Step two: compare against configuration, not type

A directive may apply to a type but not to every aircraft of that type. Check the draft against the actual configuration of each aircraft: installed part numbers, embodied modifications and service bulletins already done. The record should make this comparison easy, but the engineer makes the call.

Step three: check the compliance times

Compliance times often combine hours, cycles and calendar limits, sometimes with a grace period from the effective date. Check that the draft has interpreted "whichever occurs first" and "from the effective date" correctly, and that repetitive intervals are set up as repetitive.

Step four: look for links to other directives

Many directives supersede earlier ones, or allow an earlier action to count as compliance. Check that the draft has picked up these relationships, and that previous compliance records are linked rather than duplicated.

Step five: approve, edit or reject

Once satisfied, the engineer approves the assessment. If something was wrong, they edit it and note why. If the draft is unusable, they reject it and complete the assessment manually. In each case the record should show what the AI suggested and what the engineer decided.

What the audit trail should show

  • The directive and the source document used.
  • The draft produced and the time it was produced.
  • The engineer who reviewed it, any changes made and the reason.
  • The final applicability decision for each aircraft, with the resulting tasks.

Keep the procedure honest

Describe the use of AI in your procedures. State that the tool produces a draft, that a qualified engineer performs the assessment, and how the review is recorded. Sample completed assessments at intervals to confirm the review is real rather than a click through.

Used this way, AI removes the slow part of directive handling, which is reading and retyping, while leaving the important part, which is judgement, with the engineer.

Measures worth tracking

These measures help you see whether the approach is working. Track the trend over several months rather than reacting to a single figure.

MeasureHow to measure itWhat it tells you
Directive review lead timeHow to measure itDays from directive publication to completed assessmentWhat it tells youShows whether drafting helps the CAMO stay ahead of compliance dates
Drafts edited by engineersHow to measure itShare of AI assessments changed before approvalWhat it tells youTells you which kinds of directive need closer reading
Applicability errorsHow to measure itAssessments corrected later by sampling or auditWhat it tells youShould be zero. Any error should lead to a review of the procedure
Open assessmentsHow to measure itDirectives received but not yet assessed, by ageWhat it tells youAn early warning of a backlog building up
A
Anandbabu

Writes about aviation maintenance, airworthiness and the software that supports the people who do the work.

See how Supersonic handles thisA 45 minute walkthrough using your aircraft types and workflows.